×ðÁú¿­Ê±×îÐÂƽ̨µÇ¼

²¨·Ö¸´ÓÃÆ÷

±ê׼ЭÒé¹âÄ£¿é

¼æÈÝЭÒé¹âÄ£¿é

ÆäËüÖÖÀà¹âÆ÷¼þ

ÊÖÒÕÖ§³Ö

1U»ú¼Üʽ50G AWG DWDM(80ͨµÀ)

1U»ú¼Üʽ50G AWG DWDM(80ͨµÀ)

5.0/5 rating 1 vote

Description

80-CH 50G Athermal AWG module in 1U Rackmount

This document presents the generic specification for the 80-channel 50GHz Athermal AWG MUX/DEMUX Rackmount supplied for use in DWDM system.

Band£º

C-Band

L-Band

C+L-Band

Special

Spacing£º

50G

100G

200G

Special

Number of Channels£º

16

32

40

48

Special

Filter Shape£º

Gaussian

Broad Gaussian

Flat Top

Package£º

Module

Rack

Special

Fiber Length£º

0.5m

1m

1.5m

2m

2.5m

3m

Specify

In/Out Connector£º

None

FC/APC

FC/PC

SC/APC

SC/PC

LC/APC

LC/PC

ST/UPC

Specify

1st Channel£º

H58

C59

H59

C60

Special

This document presents the generic specification for the 80-channel 50GHz Athermal AWG MUX/DEMUX Rackmount supplied for use in DWDM system.

Athermal AWG(AAWG) have equivalent performance to standard Thermal AWG(TAWG) but require no electrical power for stabilization. They can be used as direct replacements for Thin Film Filters(Filter type DWDM module) for cases where no power is available, also suitable for outdoor applications over -30 to +70 degree in access networks. F-tone Networks’s Athermal AWG(AAWG) provide excellent optical performance, high reliability, ease of fiber handling and power saving solution in a compact package. Different input and output fibers, such as SM fibers, MM fibers and PM fiber can be selected to meet different applications. We can just offer 19” 1U rackmount package for 50G AWG products.

The planar DWDM components(Thermal/Athermal AWG) from F-tone Networks Optronics are fully qualified according to Telcordia reliability assurance requirements for fiber optic and opto-electronic components (GR-1221-CORE/UNC, Generic Reliability Assurance Requirements for Fiber Optic Branching Components, and Telcordia TR-NWT-000468, Reliability Assurance Practices for Opto-electronic Devices).

Features
Low Insertion Loss
Established silica-on-silicon
Low PDL
Low chromatic dispersion
Telcordia GR-1221-CORE qualified

ÊÂÇéζȣºÉÌÒµ¼¶0¡æ¡«+70¡æ/¹¤Òµ¼¶-40¡æ¡«+85¡æ ¿ÉÑ¡
Applications
DWDM transmission
Wavelength Routing
Optical add/drop multiplexing

Performance Specifications(Flattop Thermal AWG)

Parameter Specification
MIN Typ Max
Number of Channels 80
Number Channel Spacing£¨GHz£© 50
Cha. Center Wavelength£¨nm£© C-Band
Clear Channel Passband(GHz) ±6.5
Wavelength Stability£¨nm£© ±0.005
-1 dB Channel Bandwidth£¨nm£© 0.2    
-3 dB Channel Bandwidth£¨nm£© 0.3    
Optical Insertion Loss at ITU grid£¨dB£©   6.0 7.0
Isolation£¨dB£© Adjacent 25    
Non-Adjacent 29    
Total Channel Isolation 22    
Insertion Loss Uniformity£¨dB£©     2.0
Directivity(Mux Only)£¨dB£© 40    
Insertion Loss Ripple£¨dB£©     1.5
Optical Return loss£¨dB£© 40    
PDL/Polarization Dependent Loss in Clear Channel Band£¨dB£©   0.3 0.5
Polarization Mode Dispersion£¨ps£©     0.5
Maximum Optical Power£¨mW£©     23
MUX/DEMUX input/ output Monitoring range(dB/¡æ) -35   +23
Operating Temperature(¡æ) -5 +25 +65
Operating Humidity(%RH) 5   95
Storage Temperature(¡æ) -40   +85
Storage Humidity(%RH) 5   95
Package Size(ABS Box)(mm) L150×W65×H16
Package Size(1U Rackmount)(mm) L440×W200×H44

1¡¢IL Represents the worst case over a +/-0.01nm window around the ITU wavelength;

2¡¢PDL was measured on average polarization over a +/- 0.01nm window around the ITU wavelength.

Important Notice


Important Notice

Performance figures, data and any illustrative material provided in this data sheet are typical and must be specifically confirmed in writing by F-tone Networks before they become applicable to any particular order or contract. In accordance with the F-tone Networks policy of continuous improvement specifications may change without notice.The publication of information in this data sheet does not imply freedom from patent or other protective rights of F-tone Networks or others. Further details are available from any F-tone Networks sales representative.

Search

ÍøÕ¾µØͼ