×ðÁú¿­Ê±×îÐÂƽ̨µÇ¼

±ê×¼¹âÄ£¿é

±ê׼ЭÒé¹âÄ£¿é

¼æÈÝЭÒé¹âÄ£¿é

ÆäËüÖÖÀà¹âÆ÷¼þ

ÊÖÒÕÖ§³Ö

CXP AOC

CXP AOCÓÐÔ´¹âÀÂ

5.0/5 rating 1 vote

Specifications

  • ²úÆ·ÐͺÅ: CXP-AOC-xxx
  • ¼æÈÝÆ·ÅÆ: ȫϵÁÐ
  • ·â×°ÀàÐÍ: CXP
  • ´«ÊäËÙÂÊ: 120G
  • ´«Êä¾àÀë: VCSEL Array Transmitter/PIN Array Receiver
  • ·¢É䲨³¤: VCSEL Array Transmitter/PIN Array Receiver
  • ÎüÊÕ²¨³¤: VCSEL Array Transmitter/PIN Array Receiver
  • ÊÂÇéζÈ: ÉÌÒµ¼¶0¡æ¡«+70¡æ/¹¤Òµ¼¶-40¡æ¡«+85¡æ ¿ÉÑ¡
  • Êý×ÖÕï¶Ï: CXP AOCÓÐÔ´¹âÀÂ
  • ÎüÊÕѸËÙ¶È: CXP AOCÓÐÔ´¹âÀÂ
  • ÎüÊÕѸËÙ¶È: CXP AOCÓÐÔ´¹âÀÂ

Description

Features

  • Full duplex 12 channels 850nm parallel active optical cable            
  • Transmission data rate up to 10.3Gb/s per channel
  • Hot pluggable electrical interface
  • Differential AC-coupled high speed data interface
  • 12 channels 850nm VCSEL array
  • 12 channels PIN photo detector array
  • Multi-mode optical fibre cable of up to 300m(OM3) or 400m(OM4)
  • Low power consumption < 2W
  • Operating case temperature

Standard :  0 to +70¡ãC

Industrial : -40 to +85¡ãC

  • 3.3V power supply voltage
  • RoHS 6 compliant

Applications

  • Infiniband transmission at 12ch SDR, DDR and QDR
  • Switches, Routers
  • Data Centers
  • Other 120G Interconnect Requirement

Description

CXP-CXP active optic cables are a high performance, low power consumption, long reach interconnect solution supporting 120G Ethernet, fiber channel and PCIe. It is compliant with the 120Gbits Small Form factor Hot-Pluggable CXP-interface. F-tone CXP AOC is an assembly of 12 full-duplex lanes, where each lane is capable of transmitting data at rates up to 10Gb/s, providing an aggregated rate of 120Gb/s.

Ordering information

Part Number

Product Description

CXP-AOCG-XX

XXX=different cable lengths; 0 to +70¡ãC

CXP-AOCG-XXI

XXX=different cable lengths; -40 to +85¡ãC

 

XXX

Cable Length

03

03=3m

05

05=5m

10

10=10m

20

20=20m

50

50=50m

H0

100=100m

3H

300=300m

References£º120Gbit/s Small Form-factor Hot-Pluggable CXP-interface

Important Notice

Performance figures, data and any illustrative materialprovided in this data sheet are typical and must bespecifically confirmed in writing by F-TONE beforethey become applicable to any particular order or contract. In accordance with the F-TONE policy ofcontinuous improvement specifications may change without notice.The publication of information in thisdata sheet does not imply freedom from patent or otherprotective rights of F-TONE or others. Further detailsare available from any F-TONE sales representative.

 

Search

ÍøÕ¾µØͼ